Difference between revisions of "RPi infrasound logger"
(→Data retrieval) |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | Also see instructions from Masa-yuki-san. | ||
+ | |||
= Power = | = Power = | ||
Powered using 12V 100Ah+ [[temporary battery with sunshield|temporary battery with sunshield]]. | Powered using 12V 100Ah+ [[temporary battery with sunshield|temporary battery with sunshield]]. | ||
Line 5: | Line 7: | ||
Location of the instrument is NOT logged by the instrument itself. | Location of the instrument is NOT logged by the instrument itself. | ||
Do at least [[handheld GPS position logging|handheld GPS unit logging]]. | Do at least [[handheld GPS position logging|handheld GPS unit logging]]. | ||
− | AND | + | AND relative position with respect to 3 nearby sites using tape measurer. |
= Set up = | = Set up = | ||
Line 21: | Line 23: | ||
* "logging" | * "logging" | ||
− | When you leave the screen should be on "logging". | + | When you leave the screen should still be on "logging". |
Line 28: | Line 30: | ||
= Data retrieval = | = Data retrieval = | ||
+ | == Option 1: ssh == | ||
+ | * connect ethernet cable between RPi and laptop | ||
+ | * set laptop IP to some thing in the same range | ||
+ | * "mkdir -p ~/Hayabusa_collected_data/infrasound/instrument_ID" | ||
+ | * "rsync -a pi@192.168.1.56:~/data/ ~/Hayabusa_collected_data/infrasound/instrument_ID" | ||
+ | * you can use the opportunity to be connected to safely turn it off (if packing up at the same time): "ssh pi@192.168.1.56 sudo reboot", wait a couple of seconds, and then unplug. | ||
+ | |||
+ | == Option 2: direct card read == | ||
* Take micro SD card out, plug it in a good brand card reader directly (avoid using micro SD -> SD adapter) | * Take micro SD card out, plug it in a good brand card reader directly (avoid using micro SD -> SD adapter) | ||
* "lsblk" | * "lsblk" | ||
Line 35: | Line 45: | ||
* "umount ~/rpi_data_mount" | * "umount ~/rpi_data_mount" | ||
* Put micro SD card back into RPi (do not erase data) | * Put micro SD card back into RPi (do not erase data) | ||
− | |||
− |
Latest revision as of 11:54, 2 December 2020
Also see instructions from Masa-yuki-san.
Contents
Power
Powered using 12V 100Ah+ temporary battery with sunshield.
Localisation
Location of the instrument is NOT logged by the instrument itself. Do at least handheld GPS unit logging. AND relative position with respect to 3 nearby sites using tape measurer.
Set up
- Remove transport padding from inside the box.
- Visually check cable connexions
- Feed 2.1 mm jack to inside the box.
- Place box under sunshield (South of the battery)
Plug in / Turn on
Plug in instrument box via 2.1 mm 12V jack to cigarette lighter plug.
Inside the box, screen will display its status:
- "GPS OK"
- "starting logging"
- "logging"
When you leave the screen should still be on "logging".
Turn off
Simply unplug the power as there is no power down button (there is a small risk of SD card corruption).
Data retrieval
Option 1: ssh
- connect ethernet cable between RPi and laptop
- set laptop IP to some thing in the same range
- "mkdir -p ~/Hayabusa_collected_data/infrasound/instrument_ID"
- "rsync -a pi@192.168.1.56:~/data/ ~/Hayabusa_collected_data/infrasound/instrument_ID"
- you can use the opportunity to be connected to safely turn it off (if packing up at the same time): "ssh pi@192.168.1.56 sudo reboot", wait a couple of seconds, and then unplug.
Option 2: direct card read
- Take micro SD card out, plug it in a good brand card reader directly (avoid using micro SD -> SD adapter)
- "lsblk"
- "mkdir -p ~/Hayabusa_collected_data/infrasound/instrument_ID"
- "sudo mount /dev/sdX1" ~/rpi_data_mount
- "rsync -a ~/rpi_data_mount/home/pi/data/ ~/Hayabusa_collected_data/infrasound/instrument_ID"
- "umount ~/rpi_data_mount"
- Put micro SD card back into RPi (do not erase data)